Circuit Breaker of Motor Protection

Home » Products » Power Distribution Electrical Apparatus » Circuit Breaker of Motor Protection
Circuit Breaker of Motor Protection

GSM8-32 range motor protection circuit breaker adopts modular structure, so accessories such as auxiliary contact terminals, alarming terminals, under voltage release, shunt release, etc. can be easily mounted onto it. It can offer overload, short circuit and three phase imbalance protection functions to three phase electric motors. Also, it is ideal electrical apparatus for infrequent starting, in-operation switching off of motors. It can additionally be used as an isolator. In order to allow customers feel secure in placing orders, we design and manufacture this range of circuit breaker in strict compliance with GB14048.2, GB14048.3 and GB14048.4 standards. This makes the products successfully certified by CCC and CE.




Type Description

Main Technical Specifications
Basic specifications
TypeUtilization
category
Max. rated
current, lnm
Rated insulation
voltage, Ui
Operation PerformanceOperation frequency
(times/hour)
Electrified operation
lifespan
Non- electrified
operation lifespan
GSM8-32AC-332A690V60,000 times60,000 times120
Short-circuit breaking capacity
Release current
setting range code
Current setting
range, lr (A)
Rated current,
In (A)
Rated breaking capacity (Ue: 415V)
Rated short-circuit breaking
capacity (Icu) (KA)
Rated service short-circuit
breaking capacity (Ics) (KA)
010. 1~0.160.165050
020.16~0.250.255050
030.25~0.40.45050
040.4~0.630.635050
050.63~115050
061~1.61.65050
071.6~2.52.55050
082.5~445050
104~6.36.35050
146~10105050
169~1414157.5
2013~1818157.5
2117~2323156
2220~2525156
3224~3232105
Circuit Breaker Accessories
1. Accessory types and corresponding functions  
Accessory nameAccessory codeWiring picture Contact type Note
Auxiliary contact Internal mounted FN11One normal open, one normal closed Inserted mounted, at most one for one circuit breaker
FN20Two normal open
External mountedFW11One normal open, one normal closedLeft side mounted, at most two for each circuit breaker
FW20Two normal open
Short circuit alarming contact DB11One normal open alarming contact, one normal closed alarming contactAlarming contacts operate when there is circuit breaker short circuit condition. Left side mounted, at most one for each GSM8-32 range of products
Alarming and auxiliary contacts FB0110One normal closed alarming contact, one normal open auxiliary contact Alarming contacts operate when there is circuit breaker short circuit or overload condition. Auxiliary contacts indicate the status of main contacts. Left side mounted, at most one for GSM8-32.
FB0101One normal closed alarming contact, one normal closed auxiliary contact
FB1010One normal open alarming contact, one normal open auxiliary contact
FB1001One normal open alarming contact, one normal closed auxiliary contact
Under voltage release QY1 -Right side mounted, Left side mounted, at most one for each circuit breaker.
Shunt release FL1 -Right side mounted, Left side mounted, at most one for GSM8-32.

2. Technical parameters of accessories
Auxiliary contacts

TypeFN FW
Rated insulation voltage (V)250690
Conventional thermal current (A) 2.56
Electrified operation lifespan 60,000 times
Non-electrified operation lifespan
AC-15Rated working voltage (V)2448110/127230/24048110/127230/240380/415440500690
Rated working current (A) 21.2510.564.53.32.21.510.6
DC-13Rated working voltage (V)244860-244860110220--
Rated working current (A) 10.30.15-6531.30.5--
Alarming and auxiliary contacts
TypeAuxiliary contact Alarming contact
Rated insulation voltage (V)690 V690 V
Conventional thermal current (A) 6 A2.5 A
Electrified operation lifespan 60,000 times
Non-electrified operation lifespan
AC-15Rated voltage (V)48110/127230/240380/4154405006902448110/127230/240
Rated current (A) 64.53.32.21.510.61.510.50. 3
DC-13Rated voltage (V)244860110220--244860-
Rated current (A) 6531.30.5--10. 30.15-
Short circuit alarming contacts
Type DB11
Rated insulation voltage (V)690 V
Conventional thermal current (A) 2.5 A
Electrified operation lifespan 1000 times
Non-electrified operation lifespan
AC-15Rated voltage (V)2448110/127230/240
Rated current (A) 1.510.50.3
DC-13Rated voltage (V)244860-
Rated current (A) 10.30.15-
Under voltage release
Type QY1
Wire connection
Rated insulation voltage (V)690
Rated working voltage, Ue (V)110/127, 220/240, 380/415
Pull-in voltage (0.8~1.1) Ue
Release voltage (0.35~0.7) Ue
Shunt release
Type FL1
Rated insulation voltage (V) 690
Rated control power supply voltage, us (V)110/127, 220/240, 380/415
Pull-in voltage (0.7~1.1) us
3. Accessory combinations
Installation method Combination method Remark
Left side mounted FWThe installation sequence cannot be changed.
FW: Auxiliary contact
FB: Auxiliary and alarming contacts
DB: Short circuit alarming contacts
FW+ FW
FB
DB+ FB
FW+ DB
DB
Right side mountedQY1QY1: Under voltage release
FL1: Shunt release
Only one of them can be mounted onto the right side of the circuit breaker
FL1
Inserted FNFN: Auxiliary contact

Note: The right side mounted and inserted accessories can be combined with left side mounted ones flexibly.

Outline and Installation Dimensions (mm) Wiring Picture

As a China-based circuit breaker of motor protection manufacturer and supplier, we at TS213 also offer universal circuit breaker, molded case circuit breaker, contactor relay, switch contactor, and much more.

Feedback Form
Other Products
  • Motor Protection Circuit BreakerGSM8-80 range circuit breaker is designed for motor protection primarily. It is able to offer three-phase electric motors overload and short circuit protections, infrequent starting function, in-operation switching off function, and so on. It can also be used as an isolation switch.